期刊文献+
共找到345篇文章
< 1 2 18 >
每页显示 20 50 100
LIBS光谱技术鉴别原料药或辅料中的金属元素
1
作者 吴越 曹玲 +6 位作者 王玉 宋雪洁 Jack Zhou 胡凯 靳桂民 徐昕怡 洪小栩 《药物分析杂志》 CAS CSCD 北大核心 2019年第3期557-564,共8页
目的:建立简便、快速鉴别原料药或药用辅料中金属元素的激光诱导击穿光谱法(LIBS)。方法:以择几种含钠、钾、镁、钙、锌元素的原料药或药用辅料为模型,采用LIBS采集样品的原子光谱,基于原子光谱理论和NIST数据库,对166~800 nm波段范围内... 目的:建立简便、快速鉴别原料药或药用辅料中金属元素的激光诱导击穿光谱法(LIBS)。方法:以择几种含钠、钾、镁、钙、锌元素的原料药或药用辅料为模型,采用LIBS采集样品的原子光谱,基于原子光谱理论和NIST数据库,对166~800 nm波段范围内LIBS谱线进行辨识,鉴别样品中的金属元素。结果:获得的LIBS光谱中的特征谱线与样品中的金属元素一一对应。结论:LIBS光谱法是鉴别药物或药用辅料中金属元素的快速、准确、可靠的方法。 展开更多
关键词 激光诱导击穿光谱法(LIBS ) 原料药 药用辅料
Reaction kinetics modeling for lithium and cobalt recovery from spent lithium-ion batteries using acetic acid 预览
2
作者 Hendrik Setiawan Himawan Tri Bayu Murti Petrus Indra Perdana 《矿物冶金与材料学报:英文版》 SCIE EI CAS CSCD 2019年第1期98-107,共10页
Lithium and cobalt recovery from spent lithium-ion batteries(LIBs)is a major focus because of their increased production and usage.The conventional method for recycling spent LIBs using inorganic acids produces harmfu... Lithium and cobalt recovery from spent lithium-ion batteries(LIBs)is a major focus because of their increased production and usage.The conventional method for recycling spent LIBs using inorganic acids produces harmful byproducts.In this work,the leaching agent was substituted with a less expensive and more environmentally friendly alternative—acetic acid—and a mathematical model was developed to describe the kinetics of the recovery process.The variables used were the pH value,temperature,H2O2 concentration,and the solid-to-liquid(S/L)ratio.The mathematical model used was the shrinking core model,which was modified to accommodate an equilibrium reaction.The experimental results show that the rate of recovery of Li and Co over time was only affected by temperature.The leaching behaviors of Li and Co were found to oppose each other.An increase in temperature resulted in increased recovery of Li but decreased recovery of Co because of the product-favoring endothermic reaction of Li and the reactant-favoring exothermic reaction of Co.The product of Li has a lower entropy value than the reactant as a free-moving ion,whereas the product of Co leaching has a higher entropy value as a stiff crystal complex.Thus,temperature conditioning is a pivotal factor in the leaching of spent LIBs. 展开更多
关键词 SPENT LIBS LITHIUM COBALT kinetics modeling RECOVERY equilibrium
在线阅读 下载PDF
Calibration curve and support vector regression methods applied for quantification of cement raw meal using laser-induced breakdown spectroscopy
3
作者 贾军伟 付洪波 +3 位作者 侯宗余 王华东 倪志波 董凤忠 《等离子体科学与技术:英文版》 SCIE EI CAS CSCD 2019年第3期23-30,共8页
Laser-induced breakdown spectroscopy(LIBS)is a qualitative and quantitative analytical technique with great potential in the cement industrial analysis.Calibration curve(CC)and support vector regression(SVR)methods co... Laser-induced breakdown spectroscopy(LIBS)is a qualitative and quantitative analytical technique with great potential in the cement industrial analysis.Calibration curve(CC)and support vector regression(SVR)methods coupled with LIBS technology were applied for the quantification of three types of cement raw meal samples to compare their analytical concentration range and the ability to reduce matrix effects,respectively.To reduce the effects of fluctuations of the pulse-to-pulse,the unstable ablation and improve the reproducibility,all of the analysis line intensities were normalized on a per-detector basis.The prediction results of the elements of interest in the three types of samples,Ca,Si,Fe,Al,Mg,Na,K and Ti,were compared with the results of the wet chemical analysis.The average relative error(ARE),relative standard deviation(RSD)and root mean squared error of prediction(RMSEP)were employed to investigate and evaluate the prediction accuracy and stability of the two prediction methods.The maximum average ARE of the CC and SVR methods is 34.62%instead of 6.13%,RSD is 40.89%instead of 7.60%and RMSEP is 1.34%instead of 0.43%.The results show that SVR method can accurately analyze samples within a wider concentration range and reduce the matrix effects,and LIBS coupled with it for a rapid,stable and accurate quantification of different types of cement raw meal samples is promising. 展开更多
关键词 cement RAW MEAL calibration CURVES SVR LIBS
基于激光诱导击穿光谱的装置参数优化与硅橡胶材料的主组分分析 预览
4
作者 李勋 吕启深 +3 位作者 艾精文 陈凭 王希林 贾志东 《智慧电力》 北大核心 2019年第1期72-76,93共6页
硅橡胶材料被广泛应用于输电线路外绝缘领域,但长期运行后会逐渐发生老化现象,目前缺乏可应用于现场的、有效的老化表征手段。基于激光诱导击穿光谱技术(LIBS)可以快速获取硅橡胶样品的元素组成,并结合热重分析方法有效地测量硅橡胶的... 硅橡胶材料被广泛应用于输电线路外绝缘领域,但长期运行后会逐渐发生老化现象,目前缺乏可应用于现场的、有效的老化表征手段。基于激光诱导击穿光谱技术(LIBS)可以快速获取硅橡胶样品的元素组成,并结合热重分析方法有效地测量硅橡胶的主组分,相比于常规的元素测量手段,该方法具有良好的现场应用前景。由于光谱的质量对基于LIBS的硅橡胶老化分析影响较大,需优化LIBS参数获取高质量的光谱以进行材料组分分析。以新制高温硫化硅橡胶(HTV)为样品,对单脉冲激光能量、激光聚焦位置、光谱仪采集光谱的延迟时间对光谱质量的影响进行讨论,获得了新制HTV样品的烧蚀阈值与适用于硅橡胶材料组分分析的优化LIBS参数,最后利用热重分析仪测量了样品的主组分,发现与LIBS的测量结果有很好的对应关系。 展开更多
关键词 高温硫化硅橡胶(HTV) 激光诱导击穿光谱 参数优化 热重分析
在线阅读 免费下载
基于LIBS技术的水泥粉末在线成分分析 预览
5
作者 郭志卫 孙兰香 +6 位作者 张鹏 齐立峰 于海斌 曾鹏 周中寒 汪为 史友振 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2019年第1期278-285,共8页
在工业现场生产水泥的过程中,各种成分的含量直接影响着水泥的质量,因此如何快速准确地监测水泥中各个成分的含量意义重大。采用的实验方式为,将不经过任何预处理的水泥粉末直接放入位于二维移动平台上的物料盒中,通过激光诱导击穿光谱(... 在工业现场生产水泥的过程中,各种成分的含量直接影响着水泥的质量,因此如何快速准确地监测水泥中各个成分的含量意义重大。采用的实验方式为,将不经过任何预处理的水泥粉末直接放入位于二维移动平台上的物料盒中,通过激光诱导击穿光谱(LIBS)直接对水泥粉末表面的不同位置进行激发检测,对得到的光谱数据首先进行归一化和主成分分析等预处理操作,然后针对水泥中Ca,Si,Al,Fe,Mg五种元素,分别建立偏最小二乘(PLS)和支持向量回归(SVR)两种定量分析模型进行方法比较。此外,对比了粉末状水泥与压片式水泥两种测量方式的结果。实验结果表明,采用粉末状水泥直接测量的方式下,针对水泥样品元素浓度与所得到的光谱中特征线强度的关系,SVR方法比PLS方法更具优势,粉末状水泥直接测量的精度接近压片式测量的精度,说明LIBS技术对水泥粉末状样品直接在线测量具有可行性。 展开更多
关键词 激光诱导击穿光谱 偏最小二乘法 支持向量回归 主成分分析 水泥
在线阅读 下载PDF
Semi-supervised LIBS quantitative analysis method based on co-training regression model with selection of effective unlabeled samples
6
作者 李晓萌 陆慧丽 +1 位作者 阳建宏 常福 《等离子体科学与技术:英文版》 SCIE EI CAS CSCD 2019年第3期114-124,共11页
The accuracy of laser-induced breakdown spectroscopy(LIBS)quantitative method is greatly dependent on the amount of certified standard samples used for training.However,in practical applications,only limited standard ... The accuracy of laser-induced breakdown spectroscopy(LIBS)quantitative method is greatly dependent on the amount of certified standard samples used for training.However,in practical applications,only limited standard samples with labeled certified concentrations are available.A novel semi-supervised LIBS quantitative analysis method is proposed,based on co-training regression model with selection of effective unlabeled samples.The main idea of the proposed method is to obtain better regression performance by adding effective unlabeled samples in semi-supervised learning.First,effective unlabeled samples are selected according to the testing samples by Euclidean metric.Two original regression models based on least squares support vector machine with different parameters are trained by the labeled samples separately,and then the effective unlabeled samples predicted by the two models are used to enlarge the training dataset based on labeling confidence estimation.The final predictions of the proposed method on the testing samples will be determined by weighted combinations of the predictions of two updated regression models.Chromium concentration analysis experiments of 23 certified standard high-alloy steel samples were carried out,in which 5 samples with labeled concentrations and 11 unlabeled samples were used to train the regression models and the remaining 7 samples were used for testing.With the numbers of effective unlabeled samples increasing,the root mean square error of the proposed method went down from 1.80%to 0.84%and the relative prediction error was reduced from 9.15%to 4.04%. 展开更多
关键词 LIBS EFFECTIVE unlabeled samples CO-TRAINING SEMI-SUPERVISED LABELING CONFIDENCE estimation
A method of laser focusing control in micro-laser-induced breakdown spectroscopy
7
作者 汪为 孙兰香 +3 位作者 张鹏 郑黎明 齐立峰 董伟 《等离子体科学与技术:英文版》 SCIE EI CAS CSCD 2019年第3期31-39,共9页
This paper presents a method for the automatic adjustment of the laser defocusing amount in micro-laser-induced breakdown spectroscopy.A microscopic optical imaging system consisting of a CCD camera and a 20×obje... This paper presents a method for the automatic adjustment of the laser defocusing amount in micro-laser-induced breakdown spectroscopy.A microscopic optical imaging system consisting of a CCD camera and a 20×objective lens was adopted to realize the method.The real-time auto-focusing of the system was achieved by detecting the effective pixels of the light spot generated by the laser pointer.The focusing accuracy of the method could achieve 3μm.The element concentrations of Mn and Ni in low-alloy steels were analyzed at a crater diameter of about 35μm using the presented method.After using the presented method,the determination coefficients of Mn and Ni both exceeded 0.997,with the root-mean-square errors being 0.0133 and 0.0395,respectively.Scanning analysis was performed on the inclined plane and the curved surface by means of focusing control and non-focusing control.Ten characteristic spectral lines of Fe were selected as the analysis lines.With the focusing control,the average relative standard deviations obtained on the inclined plane and curved surface were both less than 5%,and much less than the values without focusing control,14.6%and 40.39%. 展开更多
关键词 LIBS MICROANALYSIS ablation CRATER FOCUSING control
Remote open-path laser-induced breakdown spectroscopy for the analysis of manganese in steel samples at high temperature
8
作者 崔敏超 出口祥啓 +4 位作者 王珍珍 田中诚也 全敏奎 藤田裕贵 赵升吨 《等离子体科学与技术:英文版》 SCIE EI CAS CSCD 2019年第3期52-59,共8页
A remote open-path laser-induced breakdown spectroscopy(LIBS)system was designed and studied in the present work for the purpose of combining the LIBS technique with the steel production line.In this system,the relati... A remote open-path laser-induced breakdown spectroscopy(LIBS)system was designed and studied in the present work for the purpose of combining the LIBS technique with the steel production line.In this system,the relatively simple configuration and optics were employed to measure the steel samples at a remote distance and a hot sample temperature.The system has obtained a robustness for the deviation of the sample position because of the open-path and all-optical structure.The measurement was carried out at different sample temperatures by placing the samples in a muffle furnace with a window in the front door.The results show that the intensity of the spectral lines increased as the sample temperature increased.The influence of the sample temperature on the quantitative analysis of manganese in the steel samples was investigated by measuring ten standard steel samples at different temperatures.Three samples were selected as the test sample for the simulation measurement.The results show that,at the sample temperature of 500°C,the average relative error of prediction is 3.1%and the average relative standard deviation is 7.7%,respectively. 展开更多
关键词 REMOTE open-path LIBS steel MANGANESE SAMPLE temperature quantitative ANALYSIS
液态锂与316L不锈钢焊缝的相容性初步研究 预览
9
作者 夏文星 贺平逆 +3 位作者 舒磊 马小春 韩磊 芶富均 《材料导报》 CSCD 北大核心 2018年第A01期324-328,共5页
利用金相、SEM/EDS及自主研制搭建的LIBS等分析方法,研究了316L不锈钢焊缝在350℃液态锂环境中浸泡500h的静态腐蚀行为,拟为锂回路管道焊缝与液态锂的相容性研究提供一定的数据参考。实验结果显示,316L不锈钢焊缝区在液态锂中以晶间腐... 利用金相、SEM/EDS及自主研制搭建的LIBS等分析方法,研究了316L不锈钢焊缝在350℃液态锂环境中浸泡500h的静态腐蚀行为,拟为锂回路管道焊缝与液态锂的相容性研究提供一定的数据参考。实验结果显示,316L不锈钢焊缝区在液态锂中以晶间腐蚀形式被腐蚀,焊缝区的晶界腐蚀行为更严重,但没有出现明显的相变。液态锂腐蚀后焊缝区表层的Li的渗透量约是母材区的1.55倍,Li在焊缝区和母材区的渗透深度分别约为5.48μm和3.29μm,均大于焊缝区和母材区截面观察的腐蚀疏松层厚度(~5.0μm和3.0μm)。腐蚀后,碳的质量分数增加了11.03%,表面生成了碳化物,但Cr、Ni、Mo和Mn的质量分数分别减少了2.28%、1.01%、0.47%和0.16%。焊缝表层的Cr在液态锂中的溶解损耗最严重。腐蚀前后焊缝表面的维氏硬度值之比约为3.45∶1,焊缝区的力学性能下降。总之,液态锂对316L不锈钢焊缝产生腐蚀效果。相对母材区,焊缝区更易被液态锂腐蚀。 展开更多
关键词 液态锂 316L不锈钢 焊缝 腐蚀 LIBS
在线阅读 免费下载
基于激光诱导击穿光谱的脐橙产地鉴别
10
作者 饶刚福 黄林 +8 位作者 刘木华 陈添兵 陈金印 罗子奕 许方豪 何秀文 周华茂 林金龙 姚明印 《激光与光电子学进展》 CSCD 北大核心 2018年第9期434-439,共6页
为了对脐橙产地进行快速鉴别,提出了激光诱导击穿光谱(LIBS)全光学诊断方法。选取江西赣州4区县及湖北、四川等6省市共10产地的纽荷尔脐橙,清洗表皮后直接采集等离子体羽时间演变形貌图及LIBS光谱,定性分析脐橙产地鉴别的可行性;采用1... 为了对脐橙产地进行快速鉴别,提出了激光诱导击穿光谱(LIBS)全光学诊断方法。选取江西赣州4区县及湖北、四川等6省市共10产地的纽荷尔脐橙,清洗表皮后直接采集等离子体羽时间演变形貌图及LIBS光谱,定性分析脐橙产地鉴别的可行性;采用15点平滑结合多元散射处理(15SM+MSC)预处理脐橙的LIBS光谱,分别运用主成分分析(PCA)、主成分分析结合多层感知器神经网络(PCA-MLP)鉴别脐橙产地。实验结果显示:采用一定的数据预处理方法结合PCA-MLP对全国7省市大地域范围脐橙产地鉴别的训练集总准确率为97.8%,预测集总准确率为95.3%;对赣州4区县小地域范围脐橙产地鉴别的训练集总准确率为100%,预测集总准确率为96.2%。这说明,采用合适的数据预处理及分类模型对脐橙产地进行快速鉴别具有一定的可行性。 展开更多
关键词 光谱学 脐橙 产地鉴别 LIBS PCA-MLP 等离子体羽
LIBS技术在污染土壤重金属含量分布测量中的应用 预览 被引量:1
11
作者 谷艳红 赵南京 +5 位作者 马明俊 孟德硕 贾尧 方丽 刘建国 刘文清 《光谱学与光谱分析》 CSCD 北大核心 2018年第3期982-989,共8页
诱导击穿光谱技术(LIBS)具有实时快速、多元素同时探测的优势,并且无需样品预处理,检测成本低,是土壤重金属定量分析检测的一种重要分析手段。将LIBS技术应用于冶炼厂区周围土壤中重金属的含量分布分析研究,利用Cu,Pb和Cr三种元素的特... 诱导击穿光谱技术(LIBS)具有实时快速、多元素同时探测的优势,并且无需样品预处理,检测成本低,是土壤重金属定量分析检测的一种重要分析手段。将LIBS技术应用于冶炼厂区周围土壤中重金属的含量分布分析研究,利用Cu,Pb和Cr三种元素的特征谱线强度分析了冶炼厂区周围土壤中Cu,Pb和Cr三种元素的含量分布。实验结果表明冶炼厂区土壤LIBS光谱中Cu和Pb两种元素的特征谱线强度分布与实际含量分布呈较好的线性关系,而Cr元素的特征谱线强度分布与实际含量分布相关性较差。为了提高Cr元素含量分布分析的准确性,利用CF-LIBS结合Saha方程应用于土壤Cr元素的含量分布分析中。实验结果表明基于CF-LIBS计算的Cr和Si两种元素含量比值分布与土壤Cr元素的实际含量分布之间具有良好的一致性。相比于其他的化学分析方法,LIBS技术结合CF-LIBS可以快速的对区域土壤重金属元素的含量分布进行检测,因此将LIBS技术与CF-LIBS相结合用于土壤重金属的含量分布检测中,为污染区域的重金属防治提供方向。 展开更多
关键词 LIBS 土壤 重金属 含量分布 CF-LIBS
在线阅读 下载PDF
基于激光诱导击穿光谱技术的城市土壤重金属含量检测与分析 预览 被引量:2
12
作者 李艳 翟开华 +1 位作者 李艳丽 曹沛涛 《湘潭大学自然科学学报》 2018年第3期86-88,128共4页
基于激光诱导击穿光谱(LIBS)技术,并结合偏最小二乘回归(PLSR)与最小二乘支持向量机(LSSVM)两种化学计量学分析方法,进行城市土壤中Cr元素含量检测与分析.采集了城市周边的土壤样本,并得到各个样本的LIBS谱线.采用剔除异常光谱和... 基于激光诱导击穿光谱(LIBS)技术,并结合偏最小二乘回归(PLSR)与最小二乘支持向量机(LSSVM)两种化学计量学分析方法,进行城市土壤中Cr元素含量检测与分析.采集了城市周边的土壤样本,并得到各个样本的LIBS谱线.采用剔除异常光谱和数据归一化来减少实验误差和噪声.对比分析基于PLSR和LS-SVM,建立分析谱线区间与对应的重金属元素浓度之间的定量回归模型.检测与分析结果表明,LSSVM模型的预测性能优于PLSR模型. 展开更多
关键词 重金属含量检测 LIBS 光谱测量 激光器
在线阅读 免费下载
基于主元提取神经网络LIBS光谱分析 预览
13
作者 袁备 徐送宁 +2 位作者 宁日波 李倩 韩艳丽 《沈阳理工大学学报》 CAS 2018年第6期86-91,共6页
为提高LIBS光谱定量分析精度,分别采用峰值强度特征提取法与主元特征提取法,对激发诱导击穿铜合金样品获取的Pb与基体元素Cu的特征光谱数据进行光谱特征提取,通过人工神经网络对铜合金中Pb元素的含量进行定量分析。研究结果表明,两种特... 为提高LIBS光谱定量分析精度,分别采用峰值强度特征提取法与主元特征提取法,对激发诱导击穿铜合金样品获取的Pb与基体元素Cu的特征光谱数据进行光谱特征提取,通过人工神经网络对铜合金中Pb元素的含量进行定量分析。研究结果表明,两种特征提取方法的BP-ANN(误差反向传播人工神经网络)得到的合金中Pb元素含量的定标模型相关系数良好,均可达到0.987以上;与峰值强度特征提取法相比,经主元提取的人工神经网络方法得到的合金中Pb元素含量平均检测相对误差有较大的降低,由2.3%降至0.3%,说明主元特征提取方法能有效提高LIBS光谱定量分析精度与稳定度。 展开更多
关键词 主元提取 LIBS BP-ANN 特征提取
在线阅读 下载PDF
深空探测中的激光诱导击穿光谱探测仪 预览
14
作者 舒嵘 徐卫明 +2 位作者 付中梁 万雄 袁汝俊 《深空探测学报》 2018年第5期450-457,共8页
物质成分探测是深空探测领域非常重要的技术领域,激光诱导击穿光谱技术是一种可以非接触式快速获得物质元素成分信息的手段,论文针对2020年我国首次火星探测任务提出的火星表面成分探测仪,阐述了激光诱导击穿光谱技术基本原理,国内外的... 物质成分探测是深空探测领域非常重要的技术领域,激光诱导击穿光谱技术是一种可以非接触式快速获得物质元素成分信息的手段,论文针对2020年我国首次火星探测任务提出的火星表面成分探测仪,阐述了激光诱导击穿光谱技术基本原理,国内外的技术发展现状和趋势,重点围绕火星环境、有效载荷生存性进行了分析,最后论文详细探讨了激光诱导击穿光谱技术中的数据反演和定量化技术. 展开更多
关键词 火星 激光诱导击穿光谱 LIBS 定量分析 物质成分
在线阅读 免费下载
Time-resolved evaluation of uranium plasma in different atmospheres by laser-induced breakdown spectroscopy
15
作者 Manjeet SINGH Arnab SARKAR 《等离子体科学与技术:英文版》 SCIE EI CAS CSCD 2018年第12期65-74,共10页
关键词 激光产生 血浆 时间 故障 光谱学 BOLTZMANN 评估
Effect of distances between lens and sample surface on laser-induced breakdown spectroscopy with spatial confinement
16
作者 姜振华 邵俊峰 +4 位作者 王挺峰 郭劲 张丹 陈安民 金明星 《等离子体科学与技术:英文版》 SCIE EI CAS CSCD 2018年第8期74-81,共8页
关键词 光谱学 激光 距离 空间 表面 样品 透镜 故障
Online calibration of laser-induced breakdown spectroscopy for detection of heavy metals in water
17
作者 贾尧 赵南京 +5 位作者 方丽 马明俊 孟德硕 殷高方 刘建国 刘文清 《等离子体科学与技术:英文版》 SCIE EI CAS CSCD 2018年第9期127-132,共6页
关键词 光谱学 刻度 重金属 联机 故障 激光 液体样品 标准化
利用LIBS对AlCl3溶液定量分析 预览
18
作者 奥布力喀斯木·祖农 拜合提妮萨·艾力 +2 位作者 阿拜·艾力哈孜 戴康 普拉提·艾合买提 《应用物理》 2018年第3期151-156,共6页
本文中利用激光诱导等离子体击穿光谱方法对AlCl3溶液进行了定量分析。在实验中以Al作为内标元素,将配置好不同的浓度的AlCl3溶液以射流方式产生等离子体,利用内标法和谱线–浓度法进行定量分析发现谱线面积–浓度法效果比内标法好,尤... 本文中利用激光诱导等离子体击穿光谱方法对AlCl3溶液进行了定量分析。在实验中以Al作为内标元素,将配置好不同的浓度的AlCl3溶液以射流方式产生等离子体,利用内标法和谱线–浓度法进行定量分析发现谱线面积–浓度法效果比内标法好,尤其是浓度低自吸收强时利用谱线面积–浓度法进行定标比较精确。 展开更多
关键词 LIBS 定量分析 谱线面积 液体定量分析
在线阅读 下载PDF
水分含量对激光诱导岩屑等离子体特性的影响 预览
19
作者 贾军伟 佘明军 +3 位作者 付洪波 王华东 倪志波 董凤忠 《光子学报》 CSCD 北大核心 2018年第8期25-32,共8页
对制备的七种不同湿度的岩屑样品进行实验,研究了水分含量对激光诱导岩屑等离子体特性的影响以及不同水分含量下样品中各元素浓度值的修正方法.实验分析了CaⅡ422.67nm谱线强度随岩屑样品含水量的变化,通过CaⅡ和AlⅠ各自四条谱线... 对制备的七种不同湿度的岩屑样品进行实验,研究了水分含量对激光诱导岩屑等离子体特性的影响以及不同水分含量下样品中各元素浓度值的修正方法.实验分析了CaⅡ422.67nm谱线强度随岩屑样品含水量的变化,通过CaⅡ和AlⅠ各自四条谱线的玻尔兹曼图计算了不同水分含量下的等离子体平均温度,并使用Lorentz拟合CaⅡ422.67nm谱线获得了不同水分含量岩屑等离子体的电子密度.实验结果表明,随着水分含量的增加,光谱强度、等离子体温度和电子密度均线性降低,各元素自由定标模型定量分析结果有较大差异,但不同水分含量的岩屑等离子体均满足局部热力学平衡的Mc Whirter标准,自由定标模型可以用于不同水分含量岩屑样品的分析及影响的简单修正。 展开更多
关键词 岩屑 水分含量 激光诱导击穿光谱 等离子体温度 电子密度 热力学平衡
在线阅读 免费下载
缅甸翡翠中铁元素的激光诱导击穿光谱定量检测 预览 被引量:3
20
作者 王亚军 袁心强 +3 位作者 石斌 石美钰 张倩 陈涛 《光谱学与光谱分析》 CSCD 北大核心 2018年第1期263-266,共4页
采用激光诱导击穿光谱(LIBS)技术定量分析缅甸翡翠中Fe元素的浓度。选择Fe元素的275.57nm光谱线作为定量分析谱线,选取Si元素的288.17nm光谱线作为内标谱线,选取12个缅甸翡翠样品作为研究对象,以其中9个样品绘制了传统定标法和内定标... 采用激光诱导击穿光谱(LIBS)技术定量分析缅甸翡翠中Fe元素的浓度。选择Fe元素的275.57nm光谱线作为定量分析谱线,选取Si元素的288.17nm光谱线作为内标谱线,选取12个缅甸翡翠样品作为研究对象,以其中9个样品绘制了传统定标法和内定标法的Fe元素定标曲线,并将定标曲线用于3个检验样品的Fe含量的实际预测。实验结果表明,采用传统定标方法时,定标样品光谱强度的相对标准偏差(RSD)在1.4%~8.3%之间,所建立的Fe元素浓度含量定标曲线的拟合相关系数R2为0.979,使用该方法建立的定标曲线对3个检验样品中Fe元素含量进行测定,最大相对误差为10.6%;而采用内定标法时,定标样品光谱强度的比值(IFe/ISi)的相对标准偏差(RSD)在0.9%~5.7%之间,Fe的拟合相关系数R2达到0.989,样品中Fe元素的测定相对误差均可降低到7%以下。结果证明,利用内定标法定量分析翡翠中Fe的含量比传统定标法相对误差更小,采用LIBS技术结合内定标法更适于缅甸翡翠样品中Fe元素定量分析。 展开更多
关键词 缅甸翡翠 激光诱导击穿光谱 光谱分析 传统定标 内定标
在线阅读 下载PDF
上一页 1 2 18 下一页 到第
使用帮助 返回顶部 意见反馈