期刊文献+

Method Development and Validation for the Quantification of Acrylamide in Potato Chips and Other Locally Available Food by LC-MS/MS in Bangladesh 预览

Method Development and Validation for the Quantification of Acrylamide in Potato Chips and Other Locally Available Food by LC-MS/MS in Bangladesh
在线阅读 免费下载
收藏 分享 导出
摘要 A sensitive, precise, accurate and simple in house validated Liquid Chromatography and Tandem mass spectrometric (LC-MS/MS) analytical method was developed for the quantification of acrylamide in potato chips, a probable carcinogenic and neurotoxic compound in fried food items. Acrylamide was extracted and cleaned up by QuEChERS method, then analyzed by triple quadrupole mass spectrophotometer using positive electrospray-ionization mode and d3-Acrylamide internal standard. The analyte and internal standard were separated on a reversed-phase C18 column (100 × 2.0 mm, 2.5 μm) by gradient elution with water and methanol containing 0.1% formic acid as mobile phase. The analytical method was fully validated by assessment of linearity, specificity, precision, accuracy, selectivity and robustness with relative standard deviation of less than 4%. The calibration curves were found linear with correlation coefficient (r2) of 0.9997 over the concentration range 5 - 500 μg/L. The recoveries of Acrylamide in the concentration of 250, 400, and 500 μg/L were 97% to 104%. Based on the signal to noise ratio, the lower limit of detection (LOD) and lower limit of quantification (LOQ) were achieved 2.0 μg/L and 4.0 μg/L respectively. The proposed method was also applied to other available most popular 24 types of food (265 number of sample) first time in Bangladesh. The highest level of acrylamide has been found in fried products with the range of 197.04 μg/L to 114.63 μg/L, protein-rich food lies between 79.76 to 89.14 μg/L whereas baked food products exhibited less content in the range of 35.23 to 51.17 μg/L. A sensitive, precise, accurate and simple in house validated Liquid Chromatography and Tandem mass spectrometric (LC-MS/MS) analytical method was developed for the quantification of acrylamide in potato chips, a probable carcinogenic and neurotoxic compound in fried food items. Acrylamide was extracted and cleaned up by QuEChERS method, then analyzed by triple quadrupole mass spectrophotometer using positive electrospray-ionization mode and d3-Acrylamide internal standard. The analyte and internal standard were separated on a reversed-phase C18 column (100 × 2.0 mm, 2.5 μm) by gradient elution with water and methanol containing 0.1% formic acid as mobile phase. The analytical method was fully validated by assessment of linearity, specificity, precision, accuracy, selectivity and robustness with relative standard deviation of less than 4%. The calibration curves were found linear with correlation coefficient (r2) of 0.9997 over the concentration range 5 - 500 μg/L. The recoveries of Acrylamide in the concentration of 250, 400, and 500 μg/L were 97% to 104%. Based on the signal to noise ratio, the lower limit of detection (LOD) and lower limit of quantification (LOQ) were achieved 2.0 μg/L and 4.0 μg/L respectively. The proposed method was also applied to other available most popular 24 types of food (265 number of sample) first time in Bangladesh. The highest level of acrylamide has been found in fried products with the range of 197.04 μg/L to 114.63 μg/L, protein-rich food lies between 79.76 to 89.14 μg/L whereas baked food products exhibited less content in the range of 35.23 to 51.17 μg/L.
作者 Mala Khan Md. Moniruzzaman Mamudul Hasan Razu Mala Khan;Md. Moniruzzaman;Mamudul Hasan Razu(Designated Reference Institute for Chemical Measurements (DRiCM), Dhaka, Bangladesh)
出处 《食品与营养科学(英文)》 2019年第7期876-892,共17页 Food and Nutrition Sciences
关键词 LC-MS/MS ACRYLAMIDE LINEARITY Accuracy Precision LOD LOQ LC-MS/MS Acrylamide Linearity Accuracy Precision LOD LOQ
  • 相关文献
投稿分析

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部 意见反馈