摘要 目的评价介入溶栓球囊扩张术对肺动脉栓塞治疗效果。方法8例肺动脉栓塞患者,经股静脉穿刺插管,导管导丝置于肺动脉内进行血栓捣碎、采用尿激酶冲击溶栓、球囊扩张术和24h尿激酶持续溶栓,同时给予肝素抗凝治疗。结果完全开通3例,部分开通5例。3例血氧饱和度达到100%,5例血氧饱和度达93%以上。结论介入溶栓球囊扩张术治疗肺动脉栓塞能及时开通肺动脉,恢复肺动脉血流动力学改变,纠正低氧血症,是治疗肺动脉栓塞一种有效的方法。 Objective To evaluate the interventional angioplasty by using thrombolysis and balloon dilatation in the treatment of pulmonary embolism. Methods Eight patients with pulmonary embolism were treated with interventional management including fragmentation of the thrombus, thrombolysis with urokinase flush infusion, balloon dilatation and continuing low-dose infusion for 24 hours. Anticoagulation with heparin was given simultaneously. Results The pulmonary artery was completely recanalized in three patients,
作者 孙仁华 SUN Ren-hua. Department of CT and Interventional Radiology; No. 404 Hospital of PLA; Weihai 264200; China;
出处 《介入放射学杂志》 CSCD 北大核心 2009年第1期,共3页 Journal of Interventional Radiology
关键词 肺动脉栓塞 介入治疗 pulmonary embolism interventional angioplasty thrombolysis balloon dilatation
  • 相关文献

参考文献4

二级参考文献19

  • 1[1]Millward SF, Peterson RA, Moher D, et al. LGM(Vena Tech) venacava filter: experience at a single institution[J]. J Vasc Interv Radiol,1994, 5(2): 351-356. 被引量:1
  • 2[2]Athanasoulis CA, Kaufman JA, Halpern EF, et al. Inferior vena cava filters: review of a 26-year single-center clinical experience[J]. Radiology, 2000, 216(1):54-66. 被引量:1
  • 3[3]David W, Gross WS, Colaiuta E, et al. Pulmonary embolus after vena cava filter placement[J]. Am Surg, 1999, 65(4): 341-346. 被引量:1
  • 4[4]Crochet DP, Stora O, Ferry D, et al. Vena Tech-LGM filter: long-term results of a prospective study[J]. Radiology, 1993, 188(3): 857-860. 被引量:1
  • 5[5]Poletti PA, Becker CD, Prina L, et al. Long-term results of the simon nitinol inferior vena cava filter[J]. Eur Radiol, 1998, 8(2): 289-294. 被引量:1
  • 6[6]Korbin CD, Reed RA, Taylor FC, et al. In vitro flow phantom analysis and clot-capturing ability of incompletely opened Vena Tech-LGM vena cava filters[J]. Cardiovasc Intervent Radiol, 1993, 16(1): 3-6. 被引量:1
  • 7[7]Millward SF, Marsh JI, Pon C, et al. Thrombus-trapping efficiency of the LGM(Vena Tech) and Titanium Greenfield filters in vivo[J]. J Vasc Interv Radiol, 1992, 3(1): 103-106. 被引量:1
  • 8[8]Crochet DP, Brunel P, Trogrlic S, et al. Long-term follow-up of Vena Tech-LGM filter: predictors and frequency of caval occlusion[J]. J Vasc Interv Radiol, 1999, 10(2 Pt 1): 137-142. 被引量:1
  • 9[9]Becker DM, Philbrick JT, Selby JB. Inferior vena cava filter: indications, safety, effectiveness[J]. Arch Intern Med, 1992, 152(10): 1985-1994. 被引量:1
  • 10[10]Helmberger T, Helmberger R, Holzknecht N, et al. Vena-cava-Filter Indikation, Komplikation, klinische Wertigkeit[J]. Radiology, 1998, 38(7): 614-623. 被引量:1

共引文献1685

同被引文献42

引证文献4

二级引证文献10

投稿分析

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部 意见反馈